首页 > 网管 > 网络管理 > 正文

路由器未接地引起的无法拨号故障解决

2024-09-12 21:53:55
字体:
来源:转载
供稿:网友
故障现象
  笔者某次配置了一个AM模块。出现了一个奇怪的问题。配置好后,拨入时没有Modem拨号声。只有电话的声。并且音指示灯也不亮。当笔者拔下模块上的电话线时。指示灯亮了。
配置
       620#sh run
Building configuration...
Current configuration : 866 bytes
!
version 12.2
service timestamps debug uptime
service timestamps Jog uptime
no service password-encryption
!
hostname2620
enable secret 5 $1$pUrf$9xGOg.zyxKawi9NljLHHr1
usernameuser password 0 Cisco
ip subnet-zero
!
!
no ip DOmain-lookup
!
!
!
!
interface FastEthernet0/0
ip address 136.0.0.254255.255.0.0
duplex auto
speed auto
!
interface Group-Async1
ip unnumbered FastEthernet0/0
encapsulation ppp
async default routing
async mode interactive
peer default ip address pool lab
ppp authentication chap
group-range 33 48
!
!
ip classless
no ip http server
ip pim bidir-enable
!
!
line con 0
password cisco
line 33 48
login local
modem InOut
autocommand ppp
transport input all
autoselect ppp
stopbits 1
flowcontrol hardware
line aux0
line vty 0 4
password Cisco
login
!
no scheduler allocate
end
  诊断过程
  笔者仔细检查配置文件,发现缺少ip pool,加上ip local pool lab(start ip addr)(stop ip addr),没有效果。后来笔者想到拨号采用的都是模拟信号,与接地有很大关系。没自动应答:多半是接地问题。所以直接把路由器上的接地螺钉,用一根导线接到防静电地板下面的铁支柱上,问题解决了。
  排除心得
  路由器标准接地的方法是在铺设电源线的时候放置一根地线,然后路由器的外壳接到地线上去就好?,笔者估计原来负责网络系统搭建的厂商采用的电源线忽略了地线,否则也不会出现这样的问舰。接路由器电源的时候如果有地线,一般不需要我们再接地了。
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表