slave是主从复制了,但小编在测试mysql slave主从复制出现了问题了,在此武林网小编来为各位介绍mysql数据库 slave复制异常问题解决办法,希望文章对各位有用.
以下是两种slave复制异常的情况。导致的原因都是由于跨机房同步,slave的机房突然掉电导致的。
案例一:这个错误大原因是Read_Master_Log_Pos: 1028687822的pos号在主库上是没有的.
处理方法:获取这个pos号的前一个pos号,从新开启同步,这里注意如果是row模式的话就没有问题.如果是mix的或者statement的话,就需要去分析binlog,确认具体执行到哪个pos号了,不然可能会导致数据不一致.
- (andy:db:)[(none)] 11:18:39> show slave status/G
- *************************** 1. row ***************************
- Slave_IO_State:
- Master_Host: 192.168.11.24
- Master_User: slave
- Master_Port: 3306
- Connect_Retry: 10
- Master_Log_File: mysql-bin.000342
- Read_Master_Log_Pos: 1028687822
- Relay_Log_File: localhost-relay-bin.000767
- Relay_Log_Pos: 4
- Relay_Master_Log_File: mysql-bin.000342
- Slave_IO_Running: No
- Slave_SQL_Running: Yes
- Replicate_Do_DB:
- Replicate_Ignore_DB:
- Replicate_Do_Table:
- Replicate_Ignore_Table:
- Replicate_Wild_Do_Table:
- Replicate_Wild_Ignore_Table:
- Last_Errno: 0
- Last_Error:
- Skip_Counter: 0
- Exec_Master_Log_Pos: 1028687822
- Relay_Log_Space: 120
- Until_Condition: None
- Until_Log_File:
- Until_Log_Pos: 0
- Master_SSL_Allowed: No
- Master_SSL_CA_File:
- Master_SSL_CA_Path:
- Master_SSL_Cert:
- Master_SSL_Cipher:
- Master_SSL_Key:
- Seconds_Behind_Master: NULL
- Master_SSL_Verify_Server_Cert: No
- Last_IO_Errno: 1236
- Last_IO_Error: Got fatal error 1236 from master when reading data from binary log: ‘Client requested master to start replication from position > file size; the first event ‘mysql-bin.000342′ at 1028687822, the last event read from ‘./mysql-bin.000342′ at 4, the last byte read from ‘./mysql-bin.000342′ at 4.’
- Last_SQL_Errno: 0
- Last_SQL_Error:
- Replicate_Ignore_Server_Ids:
- Master_Server_Id: 1024
- Master_UUID: e9143523-c116-11e2-a8a1-0022195d25da --Vevb.com
- Master_Info_File: /usr/local/mysql-6/data/master.info
- SQL_Delay: 0
- SQL_Remaining_Delay: NULL
- Slave_SQL_Running_State: Slave has read all relay log; waiting for the slave I/O thread to update it
- Master_Retry_Count: 86400
- Master_Bind:
- Last_IO_Error_Timestamp: 140725 06:55:26
- Last_SQL_Error_Timestamp:
- Master_SSL_Crl:
- Master_SSL_Crlpath:
- Retrieved_Gtid_Set:
- Executed_Gtid_Set:
- Auto_Position: 0
- 1 row in set (0.00 sec)
案例二:这个是由于slave的relay-log损坏了.可以考虑使用Exec_Master_Log_Pos: 439512771pos号,从新开启同步.或者使用relay_log_recovery=ON参数启动.
- (root:bi:)[(none)] 10:56:01> show slave status/G
- *************************** 1. row ***************************
- Slave_IO_State: Waiting for master to send event
- Master_Host: 172.20.100.16
- Master_User: slave
- Master_Port: 3306
- Connect_Retry: 10
- Master_Log_File: mysql-bin.000076
- Read_Master_Log_Pos: 474667384
- Relay_Log_File: localhost-relay-bin.000137
- Relay_Log_Pos: 212337426
- Relay_Master_Log_File: mysql-bin.000076
- Slave_IO_Running: Yes
- Slave_SQL_Running: No
- Replicate_Do_DB:
- Replicate_Ignore_DB:
- Replicate_Do_Table:
- Replicate_Ignore_Table:
- Replicate_Wild_Do_Table:
- Replicate_Wild_Ignore_Table:
- Last_Errno: 1594
- Last_Error: Relay log read failure: Could not parse relay log event entry. The possible reasons are: the master’s binary log is corrupted (you can check this by running ‘mysqlbinlog’ on the binary log), the slave’s relay log is corrupted (you can check this by running ‘mysqlbinlog’ on the relay log), a network problem, or a bug in the master’s or slave’s MySQL code. If you want to check the master’s binary log or slave’s relay log, you will be able to know their names by issuing ‘SHOW SLAVE STATUS’ on this slave.
- Skip_Counter: 0
- Exec_Master_Log_Pos: 439512771
- Relay_Log_Space: 474669681
- Until_Condition: None
- Until_Log_File:
- Until_Log_Pos: 0
- Master_SSL_Allowed: No
- Master_SSL_CA_File:
- Master_SSL_CA_Path:
- Master_SSL_Cert:
- Master_SSL_Cipher:
- Master_SSL_Key:
- Seconds_Behind_Master: NULL
- Master_SSL_Verify_Server_Cert: No
- Last_IO_Errno: 0
- Last_IO_Error:
- Last_SQL_Errno: 1594
- Last_SQL_Error: Relay log read failure: Could not parse relay log event entry. The possible reasons are: the master’s binary log is corrupted (you can check this by running ‘mysqlbinlog’ on the binary log), the slave’s relay log is corrupted (you can check this by running ‘mysqlbinlog’ on the relay log), a network problem, or a bug in the master’s or slave’s MySQL code. If you want to check the master’s binary log or slave’s relay log, you will be able to know their names by issuing ‘SHOW SLAVE STATUS’ on this slave.
- Replicate_Ignore_Server_Ids:
- Master_Server_Id: 1016
- Master_UUID: 7b6b6934-b981-11e3-bc82-c81f66de76ac
- Master_Info_File: /data/mysql/data/master.info
- SQL_Delay: 0
- SQL_Remaining_Delay: NULL
- Slave_SQL_Running_State:
- Master_Retry_Count: 86400
- Master_Bind:
- Last_IO_Error_Timestamp:
- Last_SQL_Error_Timestamp: 140725 10:54:50
- Master_SSL_Crl:
- Master_SSL_Crlpath:
- Retrieved_Gtid_Set:
- Executed_Gtid_Set:
- Auto_Position: 0
- 1 row in set (0.00 sec)
- [root@localhost data]# mysqlbinlog localhost-relay-bin.000137 > a.txt
- ERROR: Error in Log_event::read_log_event(): ‘read error’, data_len: 7736, event_type: 31
- ERROR: Could not read entry at offset 215681738: Error in log format or read error.
- WARNING: The range of printed events ends with a row event or a table map event that does not have the STMT_END_F flag set. This might be because the last statement was not fully written to the log, or because you are using a -stop-position or -stop-datetime that refers to an event in the middle of a statement. The event(s) from the partial statement have not been written to output.
总结:这两个错误的导致的原因是机房掉电,也就是没有crash safe.
新闻热点
疑难解答