复制代码代码如下:
Option Explicit
Const WBEM_MAX_WAIT = &H80
' Registry Hives
Const HKEY_LOCAL_MACHINE = &H80000002
Const HKEY_CURRENT_USER = &H80000001
Const HKEY_CLASSES_ROOT = &H80000000
Const HKEY_USERS = &H80000003
Const HKEY_CURRENT_CONFIG = &H80000005
Const HKEY_DYN_DATA = &H80000006
' Reg Value Types
Const REG_SZ = 1
Const REG_EXPAND_SZ = 2
Const REG_BINARY = 3
Const REG_DWORD = 4
Const REG_MULTI_SZ = 7
' Registry Permissions
Const KEY_QUERY_VALUE = &H00001
Const KEY_SET_VALUE = &H00002
Const KEY_CREATE_SUB_KEY = &H00004
Const KEY_ENUMERATE_SUB_KEYS = &H00008
Const KEY_NOTIFY = &H00016
Const KEY_CREATE = &H00032
Const KEY_DELETE = &H10000
Const KEY_READ_CONTROL = &H20000
Const KEY_WRITE_DAC = &H40000
Const KEY_WRITE_OWNER = &H80000
Class std_registry
Private Sub Class_Initialize()
Set objRegistry = Nothing
End Sub
' Connect to the reg provider for this registy object
Public Function ConnectProvider32( sComputerName )
ConnectProvider32 = False
Set objRegistry = Nothing
'On Error Resume Next
Dim oLoc : Set oLoc = CreateObject("Wbemscripting.SWbemLocator")
Dim oCtx : Set oCtx = CreateObject("WbemScripting.SWbemNamedValueSet")
' Force 64 Bit Registry
Call oCtx.Add("__ProviderArchitecture", 32 )
Call oCtx.Add("__RequiredArchitecture", True)
Dim oSvc : Set oSvc = oLoc.ConnectServer(sComputerName,"root/default","","",,,WBEM_MAX_WAIT,oCtx)
Set objRegistry = oSvc.Get("StdRegProv")
If Err.Number = 0 Then
ConnectProvider32 = True
End If
End Function
' Connect to the reg provider for this registy object
Public Function ConnectProvider64( sComputerName )
ConnectProvider64 = False
Set objRegistry = Nothing
On Error Resume Next
Dim oLoc : Set oLoc = CreateObject("Wbemscripting.SWbemLocator")
Dim oCtx : Set oCtx = CreateObject("WbemScripting.SWbemNamedValueSet")
' Force 64 Bit Registry
Call oCtx.Add("__ProviderArchitecture", 64 )
Call oCtx.Add("__RequiredArchitecture", True)
Dim oSvc : Set oSvc = oLoc.ConnectServer(sComputerName,"root/default","","",,,WBEM_MAX_WAIT,oCtx)
Set objRegistry = oSvc.Get("StdRegProv")
If Err.Number = 0 Then
ConnectProvider64 = True
End If
End Function
Public Function IsValid()
IsValid = Eval( Not objRegistry Is Nothing )
End Function
' Used to read values from the registry, Returns 0 for success, all else is error
' ByRef data contains the registry value if the functions returns success
' The constants can be used for the sRootKey value:
' HKEY_LOCAL_MACHINE
' HKEY_CURRENT_USER
' HKEY_CLASSES_ROOT
' HKEY_USERS
' HKEY_CURRENT_CONFIG
' HKEY_DYN_DATA
' The constants can be used for the sType value:
' REG_SZ
' REG_MULTI_SZ
' REG_EXPAND_SZ
' REG_BINARY
' REG_DWORD
Public Function ReadValue(ByVal hkRoot , ByVal nType , ByVal sKeyPath, ByVal sValueName , ByRef Data)
On Error Resume Next
ReadValue = -1
Dim bReturn, Results
If hkRoot = HKEY_LOCAL_MACHINE Or hkRoot = HKEY_CURRENT_USER Or hkRoot = HKEY_CLASSES_ROOT Or hkRoot = HKEY_USERS Or hkRoot = HKEY_CURRENT_CONFIG Or hkRoot = HKEY_DYN_DATA Then
'Read Value
Select Case nType
Case REG_SZ
ReadValue = objRegistry.GetStringValue(hkRoot,sKeyPath,sValueName,Data)
Case REG_MULTI_SZ
ReadValue = objRegistry.GetMultiStringValue(hkRoot,sKeyPath,sValueName,Data)
Case REG_EXPAND_SZ
ReadValue = objRegistry.GetExpandedStringValue(hkRoot,sKeyPath,sValueName,Data)
Case REG_BINARY
ReadValue = objRegistry.GetBinaryValue(hkRoot,sKeyPath,sValueName,Data)
Case REG_DWORD
ReadValue = objRegistry.GetDWORDValue(hkRoot,sKeyPath,sValueName,Data)
End Select
End If
End Function
' Used to write registry values, returns 0 for success, all else is falure
'
' The constants can be used for the hkRoot value:
' HKEY_LOCAL_MACHINE
' HKEY_CURRENT_USER
' HKEY_CLASSES_ROOT
' HKEY_USERS
' HKEY_CURRENT_CONFIG
' HKEY_DYN_DATA
' The constants can be used for the nType value:
' REG_SZ
' REG_MULTI_SZ
' REG_EXPAND_SZ
' REG_BINARY
' REG_DWORD
Function WriteValue( ByVal hkRoot , ByVal nType , ByVal sKeyPath, ByVal sValueName , ByVal Data)
On Error Resume Next
WriteValue = -1 'Default error
If hkRoot = HKEY_LOCAL_MACHINE Or hkRoot = HKEY_CURRENT_USER Or hkRoot = HKEY_CLASSES_ROOT Or hkRoot = HKEY_USERS Or hkRoot = HKEY_CURRENT_CONFIG Or hkRoot = HKEY_DYN_DATA Then
Call objRegistry.CreateKey( hkRoot , sKeyPath ) 'Create the key if not existing...
'Read Value
Select Case nType
Case REG_SZ
WriteValue = objRegistry.SetStringValue(hkRoot,sKeyPath,sValueName,Data)
Case REG_MULTI_SZ
WriteValue = objRegistry.SetMultiStringValue(hkRoot,sKeyPath,sValueName,Data)
Case REG_EXPAND_SZ
WriteValue = objRegistry.SetExpandedStringValue(hkRoot,sKeyPath,sValueName,Data)
Case REG_BINARY
WriteValue = objRegistry.SetBinaryValue(hkRoot,sKeyPath,sValueName,Data)
Case REG_DWORD
WriteValue = objRegistry.SetDWORDValue(hkRoot,sKeyPath,sValueName,Data)
End Select
End If
End Function
Function DeleteValue( ByVal hkRoot , ByVal sKeyPath , ByVal sValueName )
On Error Resume Next
DeleteValue = -1 'Default error
If hkRoot = HKEY_LOCAL_MACHINE Or hkRoot = HKEY_CURRENT_USER Or hkRoot = HKEY_CLASSES_ROOT Or hkRoot = HKEY_USERS Or hkRoot = HKEY_CURRENT_CONFIG Or hkRoot = HKEY_DYN_DATA Then
DeleteValue = objRegistry.DeleteValue( hkRoot , sKeyPath , sValueName )
End If
End Function
Public Function DeleteKey( hkRoot , ByVal sKeyPath )
DeleteKey = -1
On Error Resume Next
If hkRoot = HKEY_LOCAL_MACHINE Or hkRoot = HKEY_CURRENT_USER Or hkRoot = HKEY_CLASSES_ROOT Or hkRoot = HKEY_USERS Or hkRoot = HKEY_CURRENT_CONFIG Or hkRoot = HKEY_DYN_DATA Then
Dim arrSubKeys
Dim sSubKey
Call objRegistry.EnumKey( hkRoot, sKeyPath, arrSubkeys )
If IsArray(arrSubkeys) Then
For Each sSubKey In arrSubkeys
Call DeleteKey( hkRoot, sKeyPath & "/" & sSubKey , bForce)
Next
End If
DeleteKey = objRegistry.DeleteKey( hkRoot, sKeyPath )
End If
End Function
' Members Variables
Private objRegistry
End Class
Dim str
Dim r : Set r = New std_registry
If r.ConnectProvider32( "." ) Then
If r.ReadValue( HKEY_LOCAL_MACHINE , REG_EXPAND_SZ , "SYSTEM/CurrentControlSet/Control/Session Manager/Environment" , "ComSpec" , str )=0 Then
Wsh.echo str
Else
Wsh.echo str
End If
End If