故障现象
笔者某次配置了一个AM模块。出现了一个奇怪的问题。配置好后,拨入时没有Modem拨号声。只有电话的声。并且音指示灯也不亮。当笔者拔下模块上的电话线时。指示灯亮了。
配置
620#sh run Building configuration... Current configuration : 866 bytes
version 12.2 service timestamps debug uptime service timestamps Jog uptime no service password-encryption
hostname2620 enable secret 5 $1$pUrf$9xGOg.zyxKawi9NljLHHr1 usernameuser password 0 Cisco ip subnet-zero
no ip DOmain-lookup
interface FastEthernet0/0 ip address 136.0.0.254255.255.0.0 duplex auto speed auto
interface Group-Async1 ip unnumbered FastEthernet0/0 encapsulation ppp async default routing async mode interactive peer default ip address pool lab ppp authentication chap group-range 33 48
ip classless no ip http server ip pim bidir-enable
line con 0 password cisco line 33 48 login local modem InOut autocommand ppp transport input all autoselect ppp stopbits 1 flowcontrol hardware line aux0 line vty 0 4 password Cisco login
no scheduler allocate end |
诊断过程 笔者仔细检查配置文件,发现缺少ip pool,加上ip local pool lab(start ip addr)(stop ip addr),没有效果。后来笔者想到拨号采用的都是模拟信号,与接地有很大关系。没自动应答:多半是接地问题。所以直接把路由器上的接地螺钉,用一根导线接到防静电地板下面的铁支柱上,问题解决了。
排除心得
路由器标准接地的方法是在铺设电源线的时候放置一根地线,然后路由器的外壳接到地线上去就好?,笔者估计原来负责网络系统搭建的厂商采用的电源线忽略了地线,否则也不会出现这样的问舰。接路由器电源的时候如果有地线,一般不需要我们再接地了。
路由器未接地引起的无法拨号故障解决