HTML WMI StdRegProv 通过wmi操作注册表的vbscript实现代码 (本地或远程) Because of its length, only the code for the function itself is shown on this page. The demo script that shows how to use this function is available as a separate download. 复制代码 代码如下: Function ReadRegValue( myComputer, myRegPath, myRegValue ) ' This function reads a html' target='_blank'>value from the registry of any WMI ' enabled computer. ' ' Arguments: ' myComputer a computer name or IP address, ' or a dot for the local computer ' myRegPath a full registry key path, e.g. ' HKEY_CLASSES_ROOT/.jpg or ' HKLM/SOFTWARE/Microsoft/DirectX ' myRegValue the value name to be queried, e.g. ' InstalledVersion or "" for default ' values ' ' The function returns an array with the following elements: ' ReadRegValue(0) the computer name (the first argument) ' ReadRegValue(1) the hive number (see const declarations) ' ReadRegValue(2) the key path without the hive ' ReadRegValue(3) the value name (the third argument) ' ReadRegValue(4) the error number: 0 means no error ' ReadRegValue(5) the data type of the result ' ReadRegValue(6) the actual data, or the first element of an ' array of data for REG_BINARY or REG_MULTI_SZ ' ' Written by Rob van der Woude ' http://www.robvanderwoude.com
Dim arrRegPath, arrResult(), arrValueNames, arrValueTypes Dim i, objReg, strHive, valRegError, valRegType, valRegVal
' Assume no error, for now valRegError = 0
' Split the registry path in a hive part ' and the rest, and check if that succeeded arrRegPath = Split( myRegPath, "/", 2 ) If IsArray( arrRegPath ) Then If UBound( arrRegPath ) 1 Then valRegError = 5 Else valRegError = 5 End If
' Convert the hive string to a hive number Select Case UCase( arrRegPath( 0 ) ) Case "HKCR", "HKEY_CLASSES_ROOT" strHive = HKEY_CLASSES_ROOT Case "HKCU", "HKEY_CURRENT_USER" strHive = HKEY_CURRENT_USER Case "HKLM", "HKEY_LOCAL_MACHINE" strHive = HKEY_LOCAL_MACHINE Case "HKU", "HKEY_USERS" strHive = HKEY_USERS Case "HKCC", "HKEY_CURRENT_CONFIG" strHive = HKEY_CURRENT_CONFIG Case "HKDD", "HKEY_DYN_DATA" strHive = HKEY_DYN_DATA Case Else valRegError = 5 End Select
' Abort if any error occurred, and return an error code If valRegError 0 Then ReadRegValue = Array( myComputer, myRegPath, _ myRegPath, myRegValue, _ valRegError, "-", "-" ) Exit Function End If
' Initiate custom error handling On Error Resume Next
' Create a WMI registry object Set objReg = GetObject( "winmgmts:{impersonationLevel=impersonate}!//" _ & myComputer & "/root/default:StdRegProv" )
' Abort on failure to create the object If Err Then valRegError = Err.Number Err.Clear On Error Goto 0 ReadRegValue = Array( myComputer, myRegPath, _ myRegPath, myRegValue, _ valRegError, "-", "-" ) Exit Function End If
' Get a list of all values in the registry path; ' we need to do this in order to find out the ' exact data type for the requested value objReg.EnumValues strHive, arrRegPath( 1 ), arrValueNames, arrValueTypes
' If no values were found, we'll need to retrieve a default value If Not IsArray( arrValueNames ) Then arrValueNames = Array( "" ) arrValueTypes = Array( REG_SZ ) End If
If Err Then ' Abort on failure, returning an error code valRegError = Err.Number Err.Clear On Error Goto 0 ReadRegValue = Array( myComputer, myRegPath, _ myRegPath, myRegValue, _ valRegError, "-", "-" ) Exit Function Else ' Loop through all values in the list . . . For i = 0 To UBound( arrValueNames ) ' . . . and find the one requested If UCase( arrValueNames( i ) ) = UCase( myRegValue ) Then ' Read the requested value's data type valRegType = arrValueTypes( i ) ' Based on the data type, use the appropriate query to retrieve the data Select Case valRegType Case REG_SZ objReg.GetStringValue strHive, arrRegPath( 1 ), _ myRegValue, valRegVal If Err Then valRegError = Err.Number Case REG_EXPAND_SZ objReg.GetExpandedStringValue strHive, arrRegPath( 1 ), _ myRegValue, valRegVal If Err Then valRegError = Err.Number Case REG_BINARY ' returns an array of bytes objReg.GetBinaryValue strHive, arrRegPath( 1 ), _ myRegValue, valRegVal If Err Then valRegError = Err.Number Case REG_DWORD objReg.GetDWORDValue strHive, arrRegPath( 1 ), _ myRegValue, valRegVal If Err Then valRegError = Err.Number Case REG_MULTI_SZ ' returns an array of strings objReg.GetMultiStringValue strHive, arrRegPath( 1 ), _ myRegValue, valRegVal If Err Then valRegError = Err.Number Case REG_QWORD objReg.GetQWORDValue strHive, arrRegPath( 1 ), _ myRegValue, valRegVal If Err Then valRegError = Err.Number Case Else valRegError = 5 End Select End If Next End If
' Check if an error occurred If valRegError 0 Then valRegType = "" valRegVal = "" Err.Clear On Error Goto 0 End If
' Return the data in an array If valRegType = REG_BINARY Or valRegType = REG_MULTI_SZ Then ' First, deal with registry data which is ' returned as array instead of single value ReDim Preserve arrResult( 6 + UBound( valRegVal ) ) arrResult( 0 ) = myComputer arrResult( 1 ) = strHive arrResult( 2 ) = arrRegPath( 1 ) arrResult( 3 ) = myRegValue arrResult( 4 ) = valRegError arrResult( 5 ) = valRegType For i = 0 To UBound( valRegVal ) arrResult( 6 + i ) = valRegVal( i ) Next ReadRegValue = arrResult Else ReadRegValue = Array( myComputer, strHive, arrRegPath( 1 ), _ myRegValue, valRegError, valRegType, valRegVal ) End If
' Finished Set objReg = Nothing On Error Goto 0 End Function
Requirements: Windows version: ME, 2000, XP, Server 2003, or Vista (95, 98, NT 4 with WMI CORE 1.5) Network: any Client software: WMI CORE 1.5 for Windows 95, 98 or NT 4 Script Engine: any Summarized: Can work on any Windows computer, but WMI CORE 1.5 is required for Windows 95, 98 or NT 4. Can be used in *.vbs with CSCRIPT.EXE or WSCRIPT.EXE, as well as in HTAs.html教程